Ask a Question
CD/EUR-50L EX DT (MRP) ULPA
Manual Reverse Purge System
/tempFiles/Guest-116.JPG?applID=4&aspxerrorpath=%2fMercury-recovery-Vacuum&itID=163
/tempFiles/Guest-559.JPG?applID=4&aspxerrorpath=%2fMercury-recovery-Vacuum&itID=163 /tempFiles/Guest-560.JPG?applID=4&aspxerrorpath=%2fMercury-recovery-Vacuum&itID=163 /tempFiles/Guest-561.JPG?applID=4&aspxerrorpath=%2fMercury-recovery-Vacuum&itID=163 /tempFiles/Guest-544.JPG?applID=4&aspxerrorpath=%2fMercury-recovery-Vacuum&itID=163 /tempFiles/Guest-772.JPG?applID=4&aspxerrorpath=%2fMercury-recovery-Vacuum&itID=163

Downloads


Description Link
CD/EUR-50L EX DT (MRP) ULPA Brochure
Technical Sheet & Info More Info
CSA Certificate of Compliance
IECEx Certificate of Conformity
Schematic / Filtration System Drawing


Certifications

CD-EX Models Certified for:

CLEANING MACHINES For Hazardous Locations (Classes C1618 01 & C1618 81)

Division 1, Class I, Group D and Class II, Groups F and G, T3C
Division 1, Class II Group E (metal dust) motor and switch available
Division 2, Class I Group D and Class II, Groups F and G, T3C

CD EX Series IECEx 3rd Party Certified
External: Ex db h IIB T4 Gb Ex h tb IIIC T135°C Db IP65
Internal: Ex h IIC T6 Ga Ex h IIIC T50°C Da
IECEx LCI 10.0040X

GUARANTEED for the Safe Recovery of Combustible/Conductive Dusts

ESD Safe Vacuum Systems for Hazardous Locations are designed to prevent ignition hazards.
We use metal parts or Static Dissipative Powder Coating to prevent Electrostatic Discharge (ESD)

Complies with NFPA 77 "Recommended Practice on Static Electricity"


Features

  • Legally certified explosion proof/dust ignition proof
  • Less than 10 ohms of resistivity
  • Continuous duty 3-phase (TEFC) explosion proof/dust ignition proof motor. Third Party Certified
  • ULPA filter with an efficiency of 99.999% at 0.12 micron. Filtration efficiency of 99.9995% at 0.18 micron. Tested IEST-RP-CC001. U15 by MPPS method as per EN 1822. All of our ULPA vacuum systems are aerosol leak tested before leaving our facility - included
  • Cleanroom compatible with ISO Class 4 (former Class 10). Can be used in the Pharmaceutical industry with optional stainless steel Type 304 cart
  • Manual Reverse Purge (MRP) with static dissipative reverse purge cartridge
  • Available with Automatic Reverse Purge (ARP) filter cleaning system
  • Static conductive aluminized spun bond reverse purge cartridge is contained within a removable filter chamber
  • All stainless steel Type 304 construction (except cart)
  • Detachable recovery tank (DT) for easy disposal of recovered materials
  • Static dissipative poly liner and clip for the easy and safe disposal of recovered materials - available
  • Vertical mounting for areas with space constraints
  • Equipped with a Carriage with Suspended Motor Top (CSMT). Includes static dissipative wheels
  • Optional Ø1.5" (Ø38 mm) or Ø2" (Ø50 mm) tools & accessories
  • Motor and switch for use in the presence of conductive metal dust is available. North-America: Class II, Group E Europe: Dust Group IIIC
  • Other motor performances available

Technical Specs - North America

Switch to Europe / Asia

Specifications111631A1111631A2111631A5111632A1111632A2111632A5
Model NameCD/EUR-50L EX DT (MRP) ULPA CLASS I - GROUP D, CLASS II - GROUPS F & GCD/EUR-50L EX DT (MRP) ULPA CLASS I - GROUP D, CLASS II - GROUPS F & GCD/EUR-50L EX DT (MRP) ULPA CLASS I - GROUP D, CLASS II - GROUPS F & GCD/EUR-50L EX DT (MRP) ULPA CLASS I - GROUP D, CLASS II - GROUPS E, F & GCD/EUR-50L EX DT (MRP) ULPA CLASS I - GROUP D, CLASS II - GROUPS E, F & GCD/EUR-50L EX DT (MRP) ULPA CLASS I - GROUP D, CLASS II - GROUPS E, F & G
TypeElectric Electric Electric Electric Electric Electric
TEFC MotorYes Yes Yes Yes Yes Yes
Tension460 V230 V575 V460 V230 V575 V
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz60 Hz
PhaseThree Three Three Three Three Three
Wattage3700 W3700 W3700 W3700 W3700 W3700 W
Power5 HP5 HP5 HP5 HP5 HP5 HP
Amperage6 A12 A5 A6 A12 A5 A
Air Flow225 CFM225 CFM225 CFM225 CFM225 CFM225 CFM
Vacuum Pressure155 " H20155 " H20155 " H20155 " H20155 " H20155 " H20
VRV Setting100 " H20100 " H20100 " H20100 " H20100 " H20100 " H20
Sound Level68 dB(A)68 dB(A)68 dB(A)68 dB(A)68 dB(A)68 dB(A)
Type of Power OutletNot Included Not Included Not Included Not Included Not Included Not Included
Suction Inlet Port2.5 " 2.5 " 2.5 " 2.5 " 2.5 " 2.5 "
Cart TypeDetachable Tank (DT) Detachable Tank (DT) Detachable Tank (DT) Detachable Tank (DT) Detachable Tank (DT) Detachable Tank (DT)
Filter CleaningManual Reverse Purge (MRP) Manual Reverse Purge (MRP) Manual Reverse Purge (MRP) Manual Reverse Purge (MRP) Manual Reverse Purge (MRP) Manual Reverse Purge (MRP)
Dust Recovery Tank13.2 Gal 13.2 Gal 13.2 Gal 13.2 Gal 13.2 Gal 13.2 Gal
Length40.5 "40.5 "40.5 "40.5 "40.5 "40.5 "
Width27 "27 "27 "27 "27 "27 "
Height82.5 "82.5 "82.5 "82.5 "82.5 "82.5 "
Weight (Vacuum Only)133 lb.133 lb.133 lb.133 lb.133 lb.133 lb.
Cord Length50 ft.50 ft.50 ft.50 ft.50 ft.50 ft.
Please note that specifications are subject to change without notice